Product
![]()
TEL: 0086-512-56361008,56771008
FAX: 0086-512-58795609 Web: http://www.novaelevatorparts.com E-mail:sales@novaelevator.com ADD: NO.17, CHANGXING RD., ZHANGJIAGANG, JIANGSU, CHINA 215600 |
a. Integrated ControllerHome > Elevator Parts > Electirc Components > 6-6 Controlling Cabin > a. Integrated Controller
SpecificationsNV3000 SeriesLift Integrated Controller Elevator Integrated Controller, Lift Integrated Controller, Elevator Controlling System, Elevator Integrated Control Cabinet, Elevator Controller, NV3000 SeriesLift Integrated Controller Parallel AC380 Volt Elevator Control System for Cargo / Observation Lifts ,NV3000 Series Elevator Integrated Controller Features:
Floor Height Data Automatic Correction Each time the elevator passes through the levelling position, system will auto correct the error position with respect to the shaft parameter self-learn position data base to maintain consistent ride comfort. Elevator Position Auto Calibration Each time the elevator enters the terminal floor zone, system will self-calibrate the position counter with respect to the 1 st slowdown limit switch so that elevator over travel operation will be eliminated. Preset-able Hall Display Allows user to preset every floor display with additional number (0-9) or character (A-Z) for non-standard display. Cancellation Of Unintended Car Call Passenger needs to press the unintended floor button twice to cancel the false call. Reverse Command Cancellation When elevator travel to the terminal top or bottom floor, system cancel all the car calls registered for the reverse direction operation. Full Load By-Pass When the elevator load exceeds the full-load set value, (generally > 80% load capacity) the elevator will not respond to hall calls when passing floors. However, during this event hall calls can still be registered; they will be serviced on the travel (simplex), or by other elevator service (duplex or group control) Anti-Nuisance Function System identifies the number of passengers in the car and automatically compares the number of passengers with the number of instructions registered in the car. If an excessive number of calls are registered, then the system considers it is nuisance status and cancels all the car calls. The passengers need to re-register the desired calls again. Overload Protection When the elevator is at stationary and the load capacity excesses the rate load capacity, buzzer will sound together with the overload light on. Elevator will halt until till overload alarm is trigger off. Duplex Control Its need only 3 wires to setup without the needs of group controller board. Group Control Group control with less than 8 elevators is based on fuzzy logic control theory Independent Mode Elevator does not respond to any hall calls and closes the door automatically. Reversal Running Protection Systems continuously monitor the encoder direction via ‘AB’ phase. System will stop immediately when wrong direction is detected, brake will be applied and system will trip on level 5 fault code. Anti-Slip Protection Systems continuously monitor the speed of the elevator via ‘AB’ phase. System will stop immediately when no speed feedback from the cage, brake will be applied and system will trip on level 5 fault code. UP/DOWN Over-Speed Protection The over-speed detector gives an assurance that the speed of car cannot exceed the range of secure speed, thereby guaranteeing the safety of both passengers and cargo. Output Contactor Monitoring By monitoring the drive output current state, system can determine whether the output contactor circuit is abnormal before release the motor’s brake. Encoder Fault Protection System uses a high-speed encoder for close-loop vector control. If the encoder fails, the system stops automatically to prevent a runaway failure. Optimum Velocity Profile Generator The lift controller will optimise the velocity profile based on the desired travel distance and auto- generate velocity profile to achieve direct-to-floor landing. Time-Sharing & Peak Service Flexible setting of the time-sharing service time period and the corresponding time-sharing service floors. NV 3000 RATINGS 380/400/415V, 3 Phase Ratings (-15% to 20%: 30Ph, 323Vac to 456Vac)
220V Single-Phase, Three-Phase Ratings (-15% to 20%: 10Ph, 30Ph, 187Vac to 264Vac)
Related Products
|